Tracking pixel

Costing Guides

August 6, 2026

Author: Max Haydon

How Much Does Radiation Shielding Installation Cost?

When budgeting for an X-ray room, CT suite, dental surgery or veterinary imaging facility, it’s easy to focus on the cost of products such as lead-lined doors, lead-lined walls and lead glass.

However, specialist installation is just as important.

Radiation shielding products are designed to work together as a complete system. Even the highest quality shielding products will only perform as intended if they are installed correctly.

One of the most common questions we are asked is “How much does radiation shielding installation cost?”

As a guide, specialist installation by a two-person Raybloc team typically starts from around £1,200 per day excluding VAT, although every project is different.

The final cost depends on the size of the project, location, programme, site conditions and the complexity of the installation.

This guide explains how radiation shielding installation is costed and why correct installation is essential for maintaining shielding continuity.

Why Is Specialist Installation Required?

Radiation shielding products are not installed in the same way as standard building products.

Every lead-lined door, lead-lined window and section of wall shielding must work together to form one continuous protective barrier.

That means careful attention must be paid to:

  • Shielding continuity
  • Lead overlaps
  • Junctions between products
  • Service penetrations
  • Door frames
  • Window frames
  • Wall joints
  • Ceiling and floor interfaces

If these details are not installed correctly, the shielding performance of the room may be compromised.

Typical Radiation Shielding Installation Costs

As a general guide:

InstallationTypical Cost
Two-person specialist installation teamFrom approx. £1,200 per day ex VAT

This figure provides a useful budgeting guide, although the total installation cost will depend on the overall project.

Some smaller projects may only require a short installation period, while larger hospital developments may require installation teams on site for several weeks.

What Affects Installation Costs?

Several factors influence the cost of installing radiation shielding.

Project Size

The more shielding products being installed, the longer the installation programme is likely to be.

Projects involving multiple rooms, extensive wall shielding or numerous lead-lined doors naturally require more installation time.

Site Location

Travel and accommodation requirements may influence overall installation costs, particularly for projects located further from Raybloc’s manufacturing facility.

Access to the Installation Area

Installation costs can also be affected by:

  • Restricted access
  • Upper-floor locations
  • Lift availability
  • Working hours
  • Security requirements
  • Live healthcare environments

Projects within operational hospitals often require additional planning to minimise disruption.

Coordination with Other Trades

Radiation shielding is rarely installed in isolation.

Successful projects require coordination with:

  • Main contractors
  • Joiners
  • Drylining contractors
  • Electricians
  • Mechanical contractors
  • Medical equipment installers

Careful planning helps ensure shielding products are installed at the correct stage of the programme.

Why Shielding Continuity Matters

Radiation shielding is only effective if protection is maintained throughout the entire room.

This is often referred to as shielding continuity.

For example:

  • Lead-lined walls must connect correctly with lead-lined door frames.
  • Lead-lined windows must maintain continuity with the surrounding wall shielding.
  • Service penetrations must be detailed correctly.
  • Lead strips must be fitted over board joints.
  • Door frames and architraves must continue the shielding around openings.

A single poorly installed detail can create a weak point within the controlled area.

This is why installation is just as important as the products themselves.

Can Radiation Shielding Products Be Supplied Without Installation?

Yes.

Raybloc can provide products on a supply-only basis where installation is being carried out by others.

However, many clients choose a full supply-and-installation service to ensure:

  • Correct installation
  • Programme coordination
  • Product compatibility
  • Single-source responsibility
  • Reduced project risk

For larger or more complex projects, this can simplify project management and help avoid issues during installation.

What Information Is Needed to Price Installation?

To provide an accurate installation quotation, Raybloc will typically require:

  • Site location
  • Project drawings
  • Product schedule
  • Installation programme
  • Access arrangements
  • Site restrictions
  • Working hours
  • Delivery requirements

Understanding these details early allows installation costs to be planned more accurately.

Why Experience Matters

Radiation shielding installation is a specialist discipline.

Installers need to understand not only the products themselves but also how shielding continuity is maintained throughout the room.

Raybloc’s installation teams work with lead-lined doors, lead-lined windows, lead-lined walls and shielding products on a daily basis.

This experience helps ensure installations are completed efficiently while maintaining the shielding performance specified by the project’s Radiation Protection Advisor (RPA).

Why the Cheapest Installation Isn’t Always the Best Value

Installation costs should always be considered alongside quality and experience.

A lower installation price may not represent the best value if it results in:

  • Delays
  • Rework
  • Programme disruption
  • Shielding failures
  • Additional testing
  • Remedial works

Choosing an experienced installation team can help reduce project risk and ensure the finished room performs as intended.

Request an Installation Quote

Whether you’re fitting out a dental surgery, veterinary imaging suite, hospital radiology department or CT facility, Raybloc can provide specialist installation services alongside its range of radiation shielding products.

Send us your drawings, programme and project requirements, and our team can prepare a detailed quotation covering both the supply and installation of your radiation shielding system.

Q

How much does radiation shielding installation cost?

A

A specialist two-person installation team typically starts from around £1,200 excluding VAT per day. The total cost depends on the size and complexity of the project.

Q

Can Raybloc install the products it manufactures?

A

Yes. Raybloc offers both supply-only and full supply-and-installation services for radiation shielding projects.

Q

What affects installation costs?

A

Project size, site location, access, programme requirements, coordination with other trades and installation complexity all influence the final cost.

Q

Why is specialist installation important?

A

Radiation shielding products must be installed correctly to maintain shielding continuity throughout the controlled area. Incorrect installation can compromise the effectiveness of the shielding.

Q

Can my own contractor install the shielding?

A

Yes, although many clients choose Raybloc’s installation service to ensure the products are fitted correctly and to reduce project risk.

Q

Can Raybloc provide complete shielding solutions?

A

Yes. X-ray screens can be supplied alongside lead-lined doors, windows, wall shielding and complete radiation shielding packages.

A
Max Haydon
Follow me
Have a question?

Join to our newsletter

Get A Free Quote

X